ge-2D 1H-13C Inverse & Hybrid |
: All described pulse programs use the f2 decoupler channel for the 13C nucleus. Thus, they can also be applied on other nuclei, for instance, if a broadband probehead is available. In such case, pulses, delays and gradient strengths should be set accordingly.
ge-2D HMQC-COSY experiment
Magnitude-mode ge-2D HMQC-COSY (hmqcgpqfrl) H2BC using echo-antiecho and triple low-pass filter (h2bcetgp13) Multiplicity-edited H2BC using echo-antiecho and triple low-pass filter (h2bcedetgpl3) ge-2D HMQC-TOCSY experiment
Magnitude-mode ge-2D HMQC-TOCSY with MLEV (hmqcgpmlqf | HMQCGPML) Phase-sensitive ge-2D HMQC-TOCSY with DIPSI-2 using echo-antiecho (hmqcdietgp) Phase-sensitive ge-2D HMQC-TOCSY with DIPSI-2 using PEP (hmqcdietgpsi) Phase-sensitive ge-2D HMQC-TOCSY with DIPSI-2 using PEP using shorter overall timing (hmqcdietgpsi.2) ge-2D HSQC-TOCSY experiment
Phase sensitive ge-2D HSQC-TOCSY with MLEV using z-filter (hsqcgpmlph) Phase-sensitive ge-2D HSQC-TOCSY with MLEV using echo-antiecho (hsqcetgpml | HSQCETGPML) Phase-sensitive ge-2D HSQC-TOCSY with DIPSI-2 using PEP (hsqcdietgpsi) Phase-sensitive ge-2D HSQC-TOCSY with DIPSI-2 using PEP and adiabatic inversion pulses (hsqcdietgpsisp | HSQCDIETGPSISP) Phase-sensitive ge-2D HSQC-TOCSY with DIPSI-2 using PEP and adiabatic inversion and refocusing pulses (hsqcdietgpsisp.2) Phase-sensitive ge-2D HSQC-TOCSY with DIPSI-2 using PEP and adiabatic pulses and multiplicity editing(hsqcdiedetgpsisp.1) Phase-sensitive ge-2D HSQC-TOCSY with DIPSI-2 using PEP and adiabatic pulses and direct-peak editing(hsqcdiedetgpsisp.2) Phase-sensitive ge-2D HSQC-TOCSY with DIPSI-2 using PEP and adiabatic pulses and multiplicity and direct-peak editing(hsqcdiedetgpsisp.3) Phase-sensitive ge-2D HSQC-HECADE (hsqcdietgpjcndsisp) ge-2D HMQC-ROESY experiment
Phase-sensitive ge-2D HMQC-ROESY using echo-antiecho (hmqcetgpro) Phase-sensitive ge-2D HMQC-ROESY with T-ROESY using echo-antiecho (hmqcetgpro.2) ge-2D HMQC-NOESY experiment
Phase-sensitive ge-2D HMQC-NOESY using echo-antiecho (hmqcetgpno) ge-2D HSQC-ROESY experiment
Phase-sensitive ge-2D HSQC-ROESY using echo-antiecho and adiabatic pulses (hsqcetgprosp | HSQCETGPROSP) Phase-sensitive ge-2D HSQC-ROESY using echo-antiecho and adiabatic pulses with T-ROESY(hsqcetgprosp.2) ge-2D HSQC-NOESY experiment
Phase-sensitive ge-2D HSQC-NOESY using echo-antiecho and adiabatic pulses (hsqcetgpnosp | HSQCETGPNOSP) ge-2D ADEQUATE experiment
Phase-sensitive 1,1 ADEQUATE (adeq11etgp) Phase-sensitive 1,1 ADEQUATE using adiabatic pulse (adeq11etgpsp) Phase-sensitive 1,1 ADEQUATE with refocusing (adeq11etgprd) Phase-sensitive 1,1 ADEQUATE with refocusing using adiabatic pulse (adeq11etgprdsp) Phase-sensitive 1,1 ADEQUATE with refocusing using adiabatic pulse (adeq11etgprdsp.2) Phase-sensitive 1,n ADEQUATE (adeq1netgp) Phase-sensitive n,1 ADEQUATE (adeqn1etgp) Phase-sensitive n,n ADEQUATE (adeqnnetgp)