2D 1H-15N Inverse |
: All described pulse programs use the f3 decoupler channel for the 15N nucleus. The same results should be obtained from analog pulse programs using the f2 channel (see, for instance, gradient-enhanced 1H-13C 2D experiments. On the other hand, they could also be applied on other nuclei, for instance, if a triple-channel broadband probehead is available. In such case, pulses, delays and gradient strengths should be set accordingly.
ge-2D 1H-15N HMQC experimentge-2D 1H-15N HSQC experiment
- Phase-sensitive ge-2D 1H-15N HMQC using echo-antiecho (hmqcetf3gp)
- Phase-sensitive ge-2D 1H-15N HMQC using PEP (hmqcetf3gpsi)
- Phase-sensitive ge-2D 1H-15N HMQC using PEP and shorter overall timing( hmqcetf3gpsi.2)
- Phase-sensitive ge-2D 1H-15N HMQC using WATERGATE (3-9-19) (hmqcf3gpph19)
ge-2D 1H-15N HSQC-edited experiment
- Phase-sensitive ge-2D 1H-15N HSQC using echo-antiecho (hsqcetf3gp | HSQCETF3GP)
- Phase-sensitive ge-2D 1H-15N HSQC using PEP (hsqcetf3gpsi | HSQCETF3GPSI)
- Phase-sensitive ge-2D 1H-15N HSQC using PEP with gradients in back-inept (hsqcetf3gpsi2)
- Phase-sensitive ge-2D 1H-15N HSQC using water flip-back and echo-antiecho (hsqcetfpf3gp | HSQCETFPF3GP)
- Phase-sensitive ge-2D 1H-15N HSQC using water flip-back and PEP (hsqcetfpf3gpsi | HSQCETFPF3GPSI)
- Phase-sensitive ge-2D 1H-15N HSQC using water flip-back and PEP with gradients in back-inept (hsqcetfpf3gpsi2)
- Phase-sensitive ge-2D 1H-15N HSQC using WATERGATE (3-9-19) (hsqcf3gpph19)
- Fast-HSQC, Phase-sensitive ge-2D 1H-15N HSQC using WATERGATE (3-9-19) (fhsqcf3gpph | FHSQCF3GPPH)
- Phase-sensitive ge-2D 1H-15N HSQC using water flip-back and WATERGATE (selective pulse) (hsqcfpf3gpphwg | HSQCFPF3GPPHWG)
- Phase-sensitive ge-2D 1H-15N HSQC using XY16-CPMG and echo-antiecho (hsqcetf3gpxy)
- Phase-sensitive ge-2D 1H-15N HSQC using XY16-CPMG, water flip-back and echo-antiecho (hsqcetf3gpxy.2)
- Phase-sensitive ge-2D 1H-15N IDIS-HSQC using WATERGATE with isotopical discrimination between 15N(12CO) and 15N(13CO) (hsqcf3gpidphwg)
ge-2D 1H-15N TROSY experiment
- Phase-sensitive ge-2D 1H-15N HSQC-edited using PEP (hsqcedetf3gpsi)
- Phase-sensitive ge-2D 1H-15N HSQC-edited using PEP with gradients in back-inept (hsqcedetf3gpsi2)
ge-2D 1H-15N CRINEPT experiment
- Phase-sensitive ge-2D 1H-15N TROSY using echo-antiecho (trosyetf3gpsi | TROSYETF3GPSI)
- Phase-sensitive ge-2D 1H-15N TROSY using echo-antiecho (trosyetf3gpsi.2)
- Phase-sensitive ge-2D 1H-15N TROSY using echo-antiecho and different phase cycle (trosyetf3gpsi2)
- Phase-sensitive ge-2D 1H-15N TROSY using WATERGATE (3-9-19) (trosyf3gpph19 | TROSYF3GPPH19)
- Phase-sensitive ge-2D 1H-15N TROSY using WATERGATE and improved sensitivity (trosyf3gpphsi19 | TROSYF3GPPHSI19)
- Phase-sensitive ge-2D 1H-15N TROSY using WATERGATE and improved sensitivity with optional 13C decoupling in t1 (trosyf3gpphsi19.2 | TROSYF3GPPHSI19.2)
- Phase-sensitive ge-2D 1H-15N ZQ-TROSY using WATERGATE (trosyzqgpphwg)
- Phase-sensitive ge-2D 1H-15N TROSY using echo-antiecho and IPAP (trosyetf3gpiasi)
- Phase-sensitive ge-2D 1H-15N IDIS-TROSY using WATERGATE with isotopical discrimination between 15N(12CO) and 15N(13CO) (trosyf3gpidphwg)
ge-2D 1H-15N alpha/beta-HSQC experiment
- ge-2D 1H-15N CRINEPT using flip-back (crineptgpph)
ge-2D 1H-15N HSQC-IPAP experiment ge-2D 1H-15N HMBC experiment
- ge-2D 1H-15N alpha/beta-HSQC (hsqcetf3gpss)
Simultaneous ge-2D 1H-15N / 1H-13C HSQC experiment
- Magnitude-mode ge-2D 1H-15N HMBC (hmbcgpndqf)
- Magnitude-mode ge-2D 1H-15N HMBC using f3 channel (hmbcf3gpndqf )
- Magnitude-mode ge-2D 1H-15N HMBC with low-pass J filter and using f3 channel (hmbcf3gplpndqf )
- Phase-sensitive ge-2D 1H-15N HMBC using f3 channel (hmbcetf3gpnd )
- Phase-sensitive ge-2D 1H-15N HMBC with three-fold low-pass J filter and using f3 channel (hmbcetf3gpl3nd )
- Phase-sensitive ge-2D Simultanoeus 1H-15N / 1H-13C HSQC using echo-antiecho (hsqcetgpsismsp)